Fire is an unpredictable and constant threat, capable of igniting at any moment, anywhere. Despite our best efforts, we can never be entirely prepared for its devastating impact. However, what we can—and must—do is adhere to legal requirements and use the best materials available to prevent its spread, safeguarding both lives and property.
As Knauf Insulation, it is our responsibility to deliver insulation solutions that meet all fire protection requirements. Our solution for EI 60 fire resistance:
FIRE-TEK® DUCTPROTECT EI60 R SYSTEM
The Knauf Insulation Fire-teK® DuctProtect EI60 R SYSTEM is a system that ensures the highest safety standards as an advanced passive structural fireproof protection solution, ideal for HVAC systems.

Together with appropriate fire containment, highly efficient fireproof insulation is necessary to prevent the spread of flames, heat and smoke to other areas in case of fire.
Ventilation systems, if left unprotected, can unintentionally contribute to the spread of fire, heat, and smoke. Fire-rated rectangular ducts are a critical solution, creating fire compartments within buildings to protect lives and assets. Only proven, reliable fireproof insulation should be used in these essential horizontal and vertical ducts.
Each component is carefully assessed for fire behavior, with a primary focus on the duration of fire resistance. The classification of fire resistance for ventilation systems adheres to the EN 13501-3 standard, ensuring your installations meet the highest industry requirements for fire safety and compliance.

APPLICATION:
Knauf Insulation Fire-teK® DuctProtect EI60 R SYSTEM has been developed for use on rectangular horizontal and vertical ventilation ducts where fire resistance of up to 60 minutes is of crucial importance.
In addition to protecting in the event of a fire, the Knauf Insulation Fire-teK® DuctProtect EI60 R SYSTEM also has excellent thermal and acoustic insulation properties. Due to the dimensions of the insulation boards, the system can even be also used where space is at a premium.
The system provides guaranteed fire resistance of up to 60 minutes (if installed following the installation guidelines).

Vertical ceiling penetration for EI60

Horizontal wall penetration for EI60
Core system products:
Fire-tek® board and felt mat:

Additional products, which complement and add additional performance to the system:
Reinforcing rail
42x21x2 mm
Reasons to use Knauf Insulation Fire-teK® DuctProtect EI60 R SYSTEM:
■ Only 2 reinforcement profiles and 1 self-adhesive intumescent, at the wall penetration.
■ Simple and secure residual gap closure with mineral wool.
■ No soiling on the inside of the duct due to protruding screws/rivets.
■ No wall and floor fixation needed:
› No sound transfer from the duct to the wall.
› Faster and easier mounting.
■ Simple installation:
› Fast and easy cutting and mounting.
› No additional tools such as circular saws, drills, or electrical rivets devices are needed.
■ Revision openings certified.
■ Insulation thickness 60 mm.
"We must take every possible step to prevent the devastating spread of fire, as shown in the picture above. Professionals—including planners, engineers, constructors, installers, and manufacturers—must adhere to regulations
and select and install the appropriate materials correctly. This is one of the key factors to prevent the fatal consequences of fire.", says Amaya
Osácar, Knauf Insulation’s Fire Safety Manager