Find your product 1 - 16 of 16 Fire-teK Fire-teK BD 907 ALB Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 - 100 Thermal conductivity (10°) 0,035 W/(mK) Thermal conductivity (40°) 0,038 W/(mK) Thermal conductivity (50°) 0,039 W/(mK) Fire-teK BD 908 ALU Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 Fire-teK BD 912 ALB Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 Thermal conductivity (50°) 0,040 W/(mK) Fire-teK BD 912 ALU Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 Fire-teK BD 916 Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Fire-teK BD 918 Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 30 Thermal conductivity (50°) 0,041 W/(mK) Fire-teK Beam and Column Slab ALU* Fire protection – Beams & Columns Group Fire protection – Beams & Columns Reaction to fire A1 Thermal conductivity (40°) 0.035 W/mK Fire-teK Beam and Column Slab* Fire protection – Beams & Columns Group Fire protection – Beams & Columns Reaction to fire A1 Thermal conductivity (40°) 0.035 W/mK Fire-teK CR STD Fire protection – Irregular shapes Group Fire protection – Irregular shapes Reaction to fire A2 Maximum service temperature 700 °C Thermal conductivity (10°) 0,040 W/(mK) Fire-teK INT Fire protection – Accessories Group Fire protection – Accessories Reaction to fire E Fire-teK STICK Fire protection – Accessories Group Fire protection – Accessories Fire-teK WM 908 GGA Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 60 - 80 Fire-teK WM 908 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 80 - 100 Thermal conductivity (50°) 0,040 W/(mK) Fire-teK WM 910 GGA Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 Thermal conductivity (10°) 0.040 W/mK Fire-teK WM 910 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 40 Thermal conductivity (50°) 0,040 W/(mK) Fire-teK WM 910 GGN* Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 ( BS EN 13501-1) has been added to your comparison. has been removed from your comparison.
Fire-teK BD 907 ALB Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 - 100 Thermal conductivity (10°) 0,035 W/(mK) Thermal conductivity (40°) 0,038 W/(mK) Thermal conductivity (50°) 0,039 W/(mK)
Fire-teK BD 908 ALU Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60
Fire-teK BD 912 ALB Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60 Thermal conductivity (50°) 0,040 W/(mK)
Fire-teK BD 912 ALU Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 60
Fire-teK BD 916 Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1
Fire-teK BD 918 Fire protection – rectangular air ducts Group Fire protection – rectangular air ducts Reaction to fire A1 Thickness range 30 Thermal conductivity (50°) 0,041 W/(mK)
Fire-teK Beam and Column Slab ALU* Fire protection – Beams & Columns Group Fire protection – Beams & Columns Reaction to fire A1 Thermal conductivity (40°) 0.035 W/mK
Fire-teK Beam and Column Slab* Fire protection – Beams & Columns Group Fire protection – Beams & Columns Reaction to fire A1 Thermal conductivity (40°) 0.035 W/mK
Fire-teK CR STD Fire protection – Irregular shapes Group Fire protection – Irregular shapes Reaction to fire A2 Maximum service temperature 700 °C Thermal conductivity (10°) 0,040 W/(mK)
Fire-teK WM 908 GGA Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 60 - 80
Fire-teK WM 908 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 80 - 100 Thermal conductivity (50°) 0,040 W/(mK)
Fire-teK WM 910 GGA Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 Thermal conductivity (10°) 0.040 W/mK
Fire-teK WM 910 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 40 Thermal conductivity (50°) 0,040 W/(mK)
Fire-teK WM 910 GGN* Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 ( BS EN 13501-1)