Find your product 1 - 23 of 23 pipe section wired mat Fire-teK WM 908 GGA Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 60 - 80 Fire-teK WM 908 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 80 - 100 Thermal conductivity (50°) 0,040 W/(mK) Fire-teK WM 910 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 40 Thermal conductivity (50°) 0,040 W/(mK) Fire-teK WM 910 GGN* Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 ( BS EN 13501-1) Power-teK PB 640/680 ALU Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,039/0,042 W/(mK), depending on density Power-teK PC 600 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1 Maximum service temperature 600 °C Thermal conductivity (50°) 0,041 W/(mK) Power-teK PS 680 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1L Maximum service temperature 680 °C Thermal conductivity (50°) 0,039 W/(mK) Power-teK PS 700 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1L Maximum service temperature 680 °C Thermal conductivity (50°) 0,039 W(mK) Power-teK WM 640/660 GGV Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 GGA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 GGN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 GSA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 GSN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 SSA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Power-teK WM 640/660/680 SSN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK) Sea-teK WM 070 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Maximum service temperature 620 °C Thermal conductivity (10°) 0,035 W/(mK) Thermal conductivity (40°) 0,038 W/(mK) Sea-teK WM 080 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Thickness range 30 - 80 Maximum service temperature 640 °C Thermal conductivity (10°) 0,034 W/(mK) Thermal conductivity (40°) 0,038 W/(mK) Sea-teK WM 100 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Thickness range 30 - 80 Maximum service temperature 660 °C Thermal conductivity (10°) 0,036 W/(mK) Thermal conductivity (40°) 0,039 W/(mK) Sea-teK WM 120 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Maximum service temperature 680 °C Thermal conductivity (50°) 0,040 W/(mk) Thermo-teK PS Cld ALS HVAC Cold applications Group HVAC Cold applications Reaction to fire A2L-s1, d0 Maximum service temperature 250 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (50°) 0,035 W/(mK) Thermo-teK PS Eco HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A1L Maximum service temperature 450 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,037 W/(mK) Thermo-teK PS Eco ALU HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A2L-s1, d0 DO≤ 300 mm, A2-s1, d0 DO > 300 mm Maximum service temperature 450 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,037 W/(mK) Thermo-teK PS Pro ALU HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A2L-s1, d0 DO≤ 300 mm, A2-s1, d0 DO > 300 mm Maximum service temperature 500 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,035 W/(mK) has been added to your comparison. has been removed from your comparison.
Fire-teK WM 908 GGA Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 60 - 80
Fire-teK WM 908 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 80 - 100 Thermal conductivity (50°) 0,040 W/(mK)
Fire-teK WM 910 GGB Fire protection – circular air ducts Group Fire protection – circular air ducts Reaction to fire A1 Thickness range 40 Thermal conductivity (50°) 0,040 W/(mK)
Fire-teK WM 910 GGN* Fire protection wired mat Group Fire protection wired mat Reaction to fire A1 ( BS EN 13501-1)
Power-teK PB 640/680 ALU Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,039/0,042 W/(mK), depending on density
Power-teK PC 600 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1 Maximum service temperature 600 °C Thermal conductivity (50°) 0,041 W/(mK)
Power-teK PS 680 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1L Maximum service temperature 680 °C Thermal conductivity (50°) 0,039 W/(mK)
Power-teK PS 700 Industrial – Pipe insulation Group Industrial – Pipe insulation Reaction to fire A1L Maximum service temperature 680 °C Thermal conductivity (50°) 0,039 W(mK)
Power-teK WM 640/660 GGV Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 GGA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 GGN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 GSA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 GSN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 SSA Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Power-teK WM 640/660/680 SSN Industrial – High temperature & flexibility Group Industrial – High temperature & flexibility Reaction to fire A1 Thickness range 30 - 120 Maximum service temperature 640 °C to 680 °C, depending on density Thermal conductivity (50°) 0,040 W/(mK)
Sea-teK WM 070 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Maximum service temperature 620 °C Thermal conductivity (10°) 0,035 W/(mK) Thermal conductivity (40°) 0,038 W/(mK)
Sea-teK WM 080 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Thickness range 30 - 80 Maximum service temperature 640 °C Thermal conductivity (10°) 0,034 W/(mK) Thermal conductivity (40°) 0,038 W/(mK)
Sea-teK WM 100 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Thickness range 30 - 80 Maximum service temperature 660 °C Thermal conductivity (10°) 0,036 W/(mK) Thermal conductivity (40°) 0,039 W/(mK)
Sea-teK WM 120 Shipbuilding – Machinery, pipelines and air ducts Group Shipbuilding – Machinery, pipelines and air ducts Reaction to fire Non-combustible / IMO 2010 FTPC, Deel1 Maximum service temperature 680 °C Thermal conductivity (50°) 0,040 W/(mk)
Thermo-teK PS Cld ALS HVAC Cold applications Group HVAC Cold applications Reaction to fire A2L-s1, d0 Maximum service temperature 250 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (50°) 0,035 W/(mK)
Thermo-teK PS Eco HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A1L Maximum service temperature 450 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,037 W/(mK)
Thermo-teK PS Eco ALU HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A2L-s1, d0 DO≤ 300 mm, A2-s1, d0 DO > 300 mm Maximum service temperature 450 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,037 W/(mK)
Thermo-teK PS Pro ALU HVAC – Pipe insulation Group HVAC – Pipe insulation Reaction to fire A2L-s1, d0 DO≤ 300 mm, A2-s1, d0 DO > 300 mm Maximum service temperature 500 °C Thermal conductivity (10°) 0,033 W/(mK) Thermal conductivity (40°) 0,035 W/(mK)