Products

Find your product

Sound-teK BD 804 - 808 VBD

HVAC - Sound absorbers
Group HVAC - Sound absorbers
Reaction to fire A1
Thickness range 100 - 200
Maximum service temperature 150 °C
Thermal conductivity (40°) 0,037 W/(mK)
Thermal conductivity (50°) 0,035 W/(mK)

Sound-teK BD 804 - 808 VBS

HVAC - Sound absorbers
Group HVAC - Sound absorbers
Reaction to fire A1
Thickness range 100 - 200
Maximum service temperature 150 °C
Thermal conductivity (40°) 0,037 W/(mK)
Thermal conductivity (50°) 0,037 W/(mK)

Sound-teK BD 804 - 808 VWD

HVAC - Sound absorbers
Group HVAC - Sound absorbers
Reaction to fire A1
Thickness range 100 - 200
Maximum service temperature 150 °C
Thermal conductivity (40°) 0,037 W/(mK)
Thermal conductivity (50°) 0,035 W/(mK)

Sound-teK BD 804 - 808 WBD

HVAC - Sound absorbers
Group HVAC - Sound absorbers
Reaction to fire A1
Thickness range 100 - 200
Maximum service temperature 150 °C
Thermal conductivity (40°) 0,037 W/(mK)
Thermal conductivity (50°) 0,035 W/(mK)

Sound-teK BD 804 - 808 WBS

HVAC - Sound absorbers
Group HVAC - Sound absorbers
Reaction to fire A1
Thickness range 100 - 200
Maximum service temperature 150 °C
Thermal conductivity (40°) 0,037 W/(mK)
Thermal conductivity (50°) 0,035 W/(mK)
Group HVAC – Ducts
Reaction to fire A1
Thickness range 30 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,035-0,038 W/(mK), depending on densitye
Thermal conductivity (40°) 0,038-0,044 W/(mK), depending on density
Thermal conductivity (50°) 0,039-0,046 W/(mK), depending on density
Group HVAC – Ducts
Reaction to fire A1
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,035-0,038 W/(mK), depending on density
Thermal conductivity (40°) 0,038-0,044 W/(mK), depending on density
Thermal conductivity (50°) 0,039-0,046 W/(mK), depending on density
Group HVAC – Ducts
Reaction to fire A1
Thickness range 30 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,035-0,038 W/(mK), depending on density
Thermal conductivity (40°) 0,038-0,044 W/(mK), depending on density
Thermal conductivity (50°) 0,039-0,046 W/(mK), depending on density
Group HVAC – Ducts
Reaction to fire A1
Thickness range 50 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,035-0,038 W/(mK), depending on density
Thermal conductivity (40°) 0,038-0,044 W/(mK), depending on density
Thermal conductivity (50°) 0,039-0,046 W/(mK), depending on density
Group HVAC – Ducts
Reaction to fire A1
Thickness range 30 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,035-0,038 W/(mK), depending on density
Thermal conductivity (40°) 0,038-0,044 W/(mK), depending on density
Thermal conductivity (50°) 0,039-0,046 W/(mK), depending on density
Group HVAC – Ducts
Reaction to fire A1
Maximum service temperature 250 °C
Thermal conductivity (50°) 0.040 W/(mK)

Thermo-teK LM Air ALU

HVAC – Ducts & Pipes
Group HVAC – Ducts & Pipes
Reaction to fire A2 - s1, d0
Thickness range 25 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,036 W/(mK)
Thermal conductivity (40°) 0,042 W/(mK)
Thermal conductivity (50°) 0,043 W/(mK)

Thermo-teK LM Cld ALS

HVAC Cold applications
Group HVAC Cold applications
Reaction to fire A1
Thickness range 30 - 50
Maximum service temperature 250 °C
Thermal conductivity (40°) 0,042 W/(mK)
Thermal conductivity (50°) 0,044 W/(mK)

Thermo-teK LM Eco ALU

HVAC – Ducts & Pipes
Group HVAC – Ducts & Pipes
Reaction to fire A1 for thickness ≥ 30 mm (A2-s1,d0 for thicknesses 20 and 25 mm)
Thickness range 30 - 100
Maximum service temperature 250 °C
Thermal conductivity (10°) 0,037 W/(mK)
Thermal conductivity (40°) 0,042 W/(mK)

Thermo-teK LM Pro ALU

HVAC – Ducts & Pipes
Group HVAC – Ducts & Pipes
Reaction to fire A1 for thickness ≥ 30 mm (A2-s1,d0 for thicknesses 20 and 25 mm)
Thickness range 30 - 100
Maximum service temperature 250 °C
Thermal conductivity (40°) 0,042 W/(mK)

has been added to your comparison.