Products

Find your product
1 - 24 of 88

    Fire-teK BD 907 ALB

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1
    Thickness range 60 - 100
    Thermal conductivity (10°) 0,035 W/(mK)
    Thermal conductivity (40°) 0,038 W/(mK)
    Thermal conductivity (50°) 0,039 W/(mK)

    Fire-teK BD 908 ALU

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1
    Thickness range 60

    Fire-teK BD 912 ALU

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1
    Thickness range 60

    Fire-teK BD 916

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1

    Fire-teK BD 917 ALU*

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1
    Thickness range 45 - 90

    Fire-teK BD 918

    Fire protection – rectangular air ducts
    Group Fire protection – rectangular air ducts
    Reaction to fire A1
    Thickness range 30
    Thermal conductivity (50°) 0,041 W/(mK)

    Fire-teK Beam and Column Slab*

    Fire protection – Beams & Columns
    Group Fire protection – Beams & Columns
    Reaction to fire A1
    Thermal conductivity (40°) 0.035 W/mK

    Fire-teK CR STD

    Fire protection – Irregular shapes
    Group Fire protection – Irregular shapes
    Reaction to fire A2
    Maximum service temperature 700 °C
    Thermal conductivity (10°) 0,040 W/(mK)

    Fire-teK INT

    Fire protection – Accessories
    Group Fire protection – Accessories
    Reaction to fire E

    Fire-teK STICK

    Fire protection – Accessories
    Group Fire protection – Accessories

    Fire-teK WM 908 GGA

    Fire protection – circular air ducts
    Group Fire protection – circular air ducts
    Reaction to fire A1
    Thickness range 60 - 80

    Fire-teK WM 908 GGB

    Fire protection – circular air ducts
    Group Fire protection – circular air ducts
    Reaction to fire A1
    Thermal conductivity (50°) 0,040 W/(mK)

    Fire-teK WM 910 GGB

    Fire protection – circular air ducts
    Group Fire protection – circular air ducts
    Reaction to fire A1
    Thermal conductivity (50°) 0,040 W/(mK)

    Fire-teK WM 910 GGN*

    Fire protection wired mat
    Group Fire protection wired mat
    Reaction to fire A1 ( BS EN 13501-1)

    Power-teK BD 350/ALU*

    Industrial – High temperature
    Group Industrial – High temperature
    Reaction to fire A1
    Thickness range 40 - 100
    Maximum service temperature 350 °C
    Thermal conductivity (50°) 0,041 W/(mK)

    Power-teK BD 450 - 700

    Industrial – High temperature & flexibility
    Group Industrial – High temperature & flexibility
    Reaction to fire A1
    Thickness range 30 - 140
    Maximum service temperature 450 °C to 700 °C, depending on density
    Thermal conductivity (10°) 0.037 W/(MK) for BD 450 ALU
    Thermal conductivity (50°) 0,039 - 0,041 W/(mK)

    Power-teK BD 450 - 700 ALU

    Industrial – High temperature & flexibility
    Group Industrial – High temperature & flexibility
    Reaction to fire A1
    Thickness range 30 - 140
    Maximum service temperature 450 °C to 700 °C, depending on density
    Thermal conductivity (10°) 0.037 °C for BD 450 ALU
    Thermal conductivity (50°) 0,039 - 0,041 W/(mK), depending on density

    Power-teK BD 772/775/778

    Industrial – Compression resistance
    Group Industrial – Compression resistance
    Reaction to fire A1
    Thickness range 50 - 140
    Maximum service temperature 450 °C -only BD 775
    Thermal conductivity (10°) 0,036 W/(mK) for BD 772; 0,040 W/(mK) for BD 778
    Thermal conductivity (50°) 0,042 W/(mK) for BD 775

    Power-teK CM 620 ALU

    Industrial – Compression resistance & flexibility
    Group Industrial – Compression resistance & flexibility
    Reaction to fire A1
    Thickness range 50 - 120
    Maximum service temperature 620 °C
    Thermal conductivity (50°) 0,043 W/(mK)

    Power-teK FM 620/640/660

    Industrial – High temperature & flexibility
    Group Industrial – High temperature & flexibility
    Reaction to fire A1
    Thickness range 40 - 120
    Maximum service temperature 620 °C to 660 °C, depending on density
    Thermal conductivity (50°) 0,040 W/(mK)

    Power-teK FM 620/640/660 ALU

    Industrial – High temperature & flexibility
    Group Industrial – High temperature & flexibility
    Reaction to fire A1
    Thickness range 40 - 120
    Maximum service temperature 620 °C to 660 °C, depending on density
    Thermal conductivity (50°) 0,040 W/(mK)

    Power-teK LM 450 ALU

    Industrial – Compression resistance
    Group Industrial – Compression resistance
    Reaction to fire A1 for thickness ≥ 30 mm (A2-s1,d0 for thicknesses 20 and 25 mm)
    Thickness range 30 - 120
    Maximum service temperature 450 °C
    Thermal conductivity (50°) 0,044 W/(mK)

    Power-teK LM 550 ALU

    Industrial – Compression resistance
    Group Industrial – Compression resistance
    Reaction to fire A1
    Thickness range 30 - 120
    Maximum service temperature 550 °C
    Thermal conductivity (50°) 0,043 W/(mK)

    has been added to your comparison.

    has been removed from your comparison.